Railway Cables

NSGAFOU Cables

Application

The cables are designed for use in switch cabinets, wiring of devices, trains and buses as well as in dry rooms.

Standards

● DIN VDE 0250-602

Construction

Conductors
Flexible tinned copper to IEC 60228 class 5.

Insulation
EPR type 3G13.

Outer sheath
PCP type 5GM3.

Electrical Characteristics at 20℃

Nominal Conductor Cross Section
mm²
1.5
2.5
4.0
6.0
10
16
25
35
Conductor Resistance
Ω/km
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
Current Rating
A
31
41
58
75
103
145
194
240
Voltage Rating
KV
1.8/3

 

Nominal Conductor Cross Section
mm²
50
70
95
120
150
185
240
Conductor Resistance
Ω/km
0.393
0.277
0.21
0.164
0.132
0.109
0.0817
Current Rating
A
301
372
456
528
607
639
821
Voltage Rating
KV
1.8/3

Mechanical and Thermal Properties

Minimum Bending Radius: 4×OD
Temperature Range:-25℃ to +80℃ (during operation); -10℃ to +60℃ (during installation)

Dimensions And Weight

Cable Code
No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm²
No. & Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km

RF602-NSGAFOU-1G1.5

1×1.5

30/0.25

1.3

6.5

59

RF602-NSGAFOU-1G2.5

1×2.5

50/0.25

1.3

6.8

74

RF602-NSGAFOU-1G4

1×4.0

56/0.3

1.3

7.7

94

RF602-NSGAFOU-1G6

1×6.0

84/0.3

1.3

8.3

118

RF602-NSGAFOU-1G10

1×10.0

80/0.4

1.5

9.2

163

RF602-NSGAFOU-1G16

1×16.0

126/0.4

1.5

10.1

220

RF602-NSGAFOU-1G25

1×25.0

196/0.40

1.8

12.5

336

RF602-NSGAFOU-1G35

1×35.0

276/0.40

1.8

14.0

470

RF602-NSGAFOU-1G50

1×50.0

396/0.40

1.8

15.5

581

RF602-NSGAFOU-1G70

1×70.0

360/0.50

1.8

17.0

772

RF602-NSGAFOU-1G95

1×95.0

475/0.50

2.2

19.5

1030

RF602-NSGAFOU-1G120

1×120.0

608/0.50

2.2

21.2

1280

RF602-NSGAFOU-1G150

1×150.0

756/0.50

2.2

23.5

1650

RF602-NSGAFOU-1G185

1×185.0

925/0.50

2.4

25.6

2050

RF602-NSGAFOU-1G240

1×240.0

1221/0.50

2.6

27.3

2590